30
7 If the [Jog switch] is turned, the digital display will blink.
Select the desired timer operation.
* Timer selection is also possible in ‘NAVI mode’.
8 Press the [Jog switch] to enter the ‘timer period setting’ state.
* The factory setting is ‘10 ms’.
B If the [Jog switch] is pressed, the digital display will quickly
blink 3 times, confirming the setting.
0 Sets the timer period for the ON-delay timer.
A Sets the OFF-delay timer period for ON-delay • OFF-delay
timer settings, and the ONE SHOT timer period for
ON-delay • ONE SHOT timer settings.
D Press the [MODE key] 3 times or keep it pressed for 2 sec.
or more, the amplifier will return to ‘RUN mode’ (normal
sensing operation).
C The output that has been set will be displayed.
9 Turn the [Jog switch] to select the desired timer period .
When using the ON-delay • OFF-delay timer combination or
the ON-delay • ONE SHOT timer combination, each timer
can be set individually.
* Timer period will be switched to the values set by timer
operations, unless ‘Without timer’ is chosen.
Turn the Jog switch to select
the desired timer operation.
The digital display will quickly
blink 3 times to confirm the setting.
In case of
ON-delay • OFF-delay
In case of
ON-delay •
ONE SHOT
Turn the Jog switch to select
the desired timer period.
Press the
Jog switch.
Turn the Jog switch to select
the desired timer period.
Turn the Jog switch to select
the desired timer period.
Press the
Jog switch.
Press the Jog switch.
Press the MODE key
3 times or keep it
pressed for 2 sec.
or more.
Without timer
ON-delay • OFF-delay
ON-delay
•
ONE SHOT
OFF-delay ON-delay
ONE SHOT
When using the ON-delay • OFF-delay
timer combination or the ON-delay •
ONE SHOT timer combination