Adjust Lock Setting Function
This function allows the selection of whether the ‘threshold value fine adjustment
mode’ is enabled (Adjustment Lock OFF) or disabled (Adjustment Lock ON) in
RUN mode (normal sensing operation).
When set to ‘Adjust Lock OFF’, the threshold value can be adjusted directly in
‘RUN mode’ (normal sensing operation).
Refer to p.52 for setting procedure
:
Setting Reset Function
This function will cause all configuration settings to revert to factory settings.
However, any settings that have been saved within the data bank will not be changed.
Please refer to the ‘3-2. Factory Settings’ on p.4.
Refer to p.53 for setting procedure
[Notes]
If function settings (Response time, Hysteresis, L-ON / D-ON, Display setting, Adjust lock setting function, Timer operation
and Timer period) are changed, the changes will be reflected in the configuration and the numerical value of the direct code
will be automatically updated as a result.
If Timer operation is set to ‘NON (without timer)’, then the Timer period will be forced to change to OFF.
If the Timer period in the fourth digit is set to ‘OFF (code: 0)’, then the Timer operation in the third digit will change
automatically to NON (without timer) (code: 0 or 4).
If the Timer period is set to a time that does not correspond to a direct code value, then the remaining codes, other than that
in the fourth digit, will still remain valid. At this time, the digital display of the FX-301 will indicate ‘ ’.
•
•
•
•
:
Interference Prevention Switching Function
The number of fibers that can be installed close together can be changed from 4
to 8. However, the response time will be twice as long.
If the response time is set to ‘H-SP (ultra high-speed)’, 2 units and 4 units can be
set.
If the response time is set to ‘U-LG (ultra long-range)’, 8 units and 16 units can be
set.
Refer to p.54 for setting procedure
FX-305(P) only