EasyManua.ls Logo

Panasonic DP-0 Series - Page 10

Panasonic DP-0 Series
11 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10
Digital Pressure Sensor DP-0 SERIES
36.436.4
1.433
DIMENSIONS (Unit: mm in)
The CAD data can be downloaded from the website.
MS-DP1-8 MS-DP1-3
Panel mounting bracket (Optional), Front protection cover (Optional)
Mounting drawing with DP‑00□
8.5
0.335
11
0.433
Panel thickness
dimension 1 to 3 mm
0.039 to 0.118 in
7.2
0.283
12.8
0.504
ø8.35 ø0.329
4.9 0.193
Front protection
cover
View A
Connector
A
(39.3 1.547)
34.5 1.358
50 1.969
33.4 1.315
(52 2.047 max.)
34.5
1.358
33.4
1.315
( )
20
0.787
Material: Polyacetal (Panel mounting bracket)
Polycarbonate (Front protection cover)
CN-14A(-R)-C
Connector attached cable (Optional, CN-14A-C2 is attached to the sensor)
L
ø3.7 ø0.146 cable
35
1.378
( )
8
0.315
( )
8
0.315
( )
50
1.969
( )
Model No. Cable length L (mm in)
CN-14A(-R)-C1
1,000 39.370
CN-14A(-R)-C2
2,000 78.740
CN-14A(-R)-C3
3,000 118.110
CN-14A(-R)-C5
5,000 196.850
MS-DP1-7
M5 male thread
Material: Brass (Nickel plated)
Weight: 10 g approx.
Gasket
Rc
1
/8
female thread
( )
15.8
0.622
14
0.551
7.8
0.307
0.5
0.020
( )
3.5
0.138
11 0.433
10 0.394
8
0.315
Assembly dimensions
Conversion bushing (Optional)
When 1 unit is installed
31
0
−0.4
31
0
−0.4
1.220
0
−0.016
1.220
0
0.016
When “n” units are installed
horizontally in series
31 1.220 × n + 3.5 0.138 × (n-1)
55
2.165
or more
31
0
−0.4
1.220
0
0.016
When “n” units are installed
vertically in series
31 1.220 × n +
3.5
0.138 × (n-1)
55 2.165
or more
31
0
−0.4
1.220
0
0.016
Note: The panel thickness should be
1 to 3 mm 0.039 to 0.118 in.
Note: The panel thickness should be
1 to 3 mm 0.039 to 0.118 in.
Panel cut-out dimensions

Related product manuals