10
Digital Pressure Sensor DP-0 SERIES
36.436.4
1.433
DIMENSIONS (Unit: mm in)
The CAD data can be downloaded from the website.
MS-DP1-8 MS-DP1-3
Panel mounting bracket (Optional), Front protection cover (Optional)
Mounting drawing with DP‑00□
8.5
0.335
11
0.433
Panel thickness
0.039 to 0.118 in
7.2
0.283
12.8
0.504
ø8.35 ø0.329
4.9 0.193
Front protection
cover
View A
Connector
A
(39.3 1.547)
34.5 1.358
50 1.969
33.4 1.315
(52 2.047 max.)
34.5
33.4
1.315
( )
20
0.787
Material: Polyacetal (Panel mounting bracket)
Polycarbonate (Front protection cover)
CN-14A(-R)-C□
Connector attached cable (Optional, CN-14A-C2 is attached to the sensor)
L
35
1.378
( )
8
0.315
( )
8
0.315
( )
50
1.969
( )
Model No. Cable length L (mm in)
CN-14A(-R)-C1
1,000 39.370
CN-14A(-R)-C2
2,000 78.740
CN-14A(-R)-C3
3,000 118.110
CN-14A(-R)-C5
5,000 196.850
MS-DP1-7
M5 male thread
Material: Brass (Nickel plated)
Weight: 10 g approx.
Gasket
Rc
1
/8
female thread
( )
15.8
0.622
14
0.551
7.8
0.307
0.5
0.020
( )
3.5
0.138
11 0.433
10 0.394
8
0.315
Assembly dimensions
Conversion bushing (Optional)
When 1 unit is installed
31
−0.4
31
0
−0.4
1.220
0
−0.016
1.220
0
−
When “n” units are installed
horizontally in series
31 1.220 × n + 3.5 0.138 × (n-1)
55
2.165
or more
31
0
−0.4
1.220
0
−
When “n” units are installed
vertically in series
31 1.220 × n +
0.138 × (n-1)
55 2.165
31
−0.4
1.220
0
−0.016
Note: The panel thickness should be
1 to 3 mm 0.039 to 0.118 in.
Note: The panel thickness should be
1 to 3 mm 0.039 to 0.118 in.
Panel cut-out dimensions