102
UF-9000
APR 2006
Ver. 3.0
DP-180/190
4.3.13. Recording Paper Creases
START
No
Yes
Is the recording paper damp?
Replace the recording paper.
END
Are there any foreign particles 
or stains in the Fuser Unit?
1. Remove any foreign particles
     or clean the stains.
Are there any foreign particles 
or stains in the paper path?
Yes
No
Remove any obstructions and 
clean the paper path.
No
Yes
Is the recording paper skewing?
Ensure the paper is set under the 
Paper Separation Clips in the 
Cassette.
No
Yes
2. Replace the Fuser Unit.
Paper Travel