237
UF-9000
APR 2006
Ver. 3.0
DP-180/190
CN018
CN017-2 +24VIR Main Motor-2 +24 VDC through Front
Cover Safety Interlock SW
CN017-3 24VGND Main Motor-3 Ground
CN017-4 24VGND Main Motor-4 Ground
CN017-5 nMMCTL Main Motor-5 Main Motor Control Signal
CN017-6 nMMLD Main Motor-6 Main Motor Rotation Signal
CN017-7 nMMHALF Main Motor-7 Motor Rotation Speed
Control
H: 1908.35 rpm
L: 954.18 rpm
Engine
Control
PCB
Pin No.
Signal Name Destination Signal Waveform Function
CN018-1 FANPER Fan Motor-1 +24VDC Fan Power
CN018-2 24VGND Fan Motor-2 Ground
CN018-3 FANNERR Fan Motor-3 Fan Error Detection Signal
Engine
Control
PCB
Pin No.
Signal Name Destination Signal Waveform Function
+24
V
+5
V
Cover Open
Sleep &
Shutdown
0V
0V
Main Motor
Control
Enable
+5V
0V
Main Motor
Rotation
Enable
+5V
0V
+5V (H
)
0V (L
)
+24
V
0V
+5V
0V

Table of Contents