The newly controlled features and intervals are as follows.
1. Grid Voltage Feedback for Image Density Control
QUANTUM uses the Copy Density information, interpreted by the Image Density Sensors, to
control the Grid Voltage (1) [600 - 900 V] along with the Toner Density (±0.9%) and conveys it
to the Toner Density Controller as a feedback signal.
2. Long Run Operation Compensation
Under Long Run Operation Environment, the Toner Density is also controlled with the Long 
Run Operation Compensation Parameter activated by the Timer / Counter (2) every 1k-sheet 
interval.
3. Developer Compensation 
The Toner Density is also controlled with Developer Compensation Parameter activated by 
the Timer / Counter (3) when reaching the 150k, 180k and 210k-sheet count.
4. Initialization
The Developer Parameter is initialized by the Timer / Counter (4) when the machine is non 
operational for over one hour.
5. Humidity and Temperature Compensation 
Humidity and Temperature factors are also compensated with the Sensors (5) and the TDC 
Controller Compensation Software by stabilizing the Toner Density under the various High 
Temperature and High Humidity environments.