8 CONTROL OF THE AIR-MASSAGE OPERATION
Air massage functions with the operations of the pump unit x 1pc, 3-way electromagnetic valve x 1pc, and 2-way
electromagnetic valve x 2pcs.
1. Air massage functions with the pump unit and the electromagnetic valves.
2. Every time you press the leg massage button, the modes change from stop - weak - strong - stop.
3. 16-minute timer operates and the massage operation stops.
4. The air pump and the all the electromagnetic valves are off when in the stop mode.
5. The air control function stops when the reclining lift motor operates.
(The outputs of the air pump and the electromagnetic valves are off: ventilation)
When the operation resumes after being in off positions, the four-second off period is maintained.
However, the LED lights on when the leg massage button is on.
Air pattern
Operation step: 7 steps
Interval: Approx. 30 seconds
a1) Air is pumped in to the ankles. (approx. 5 seconds)
a2) a3) The electromagnetic valves are switched. (approx. 2 seconds)
a4) Air is pumped in to the calves. (approx. 7 seconds)
a5) a6) The electromagnetic valves are switched and the air pressure is maintained.
a7) It ventilates. (approx. 11 seconds)