32
Installation Instructions
For Installer
The wires in the mains lead tted to this oven are coloured in accordance with the following
code:
• Green and Yellow - Earth (
)
• Blue - Neutral (N)
• Brown - Live (L)
Proper size of exible cord and electric
wiring must be installed to avoid smoke
emission and re hazards.
220 - 240 V
16 A
N
L
< To use 3 core exible cord; 2.5 mm² >.
Installation of external switch is
necessary near to oven.
Oven wiring
Power supply
IMPORTANT:
Correct installation is the responsibility of the installer. Any malfunction or accident
resulting from the failure to follow the Installation Instructions is not covered by the
warranty.