25
KX-NS0154
12.3. How to Replace the LLP (Leadless Leadframe Package) IC and IC
ground plate
12.3.1. Preparation
PbF (: Pb free) Solder
Soldering Iron
Tip Temperature of 700 F ± 20 F (370 C ± 10 C)
Note:
We recommend a 30 to 40 Watt soldering iron. An expert may be able to use a 60 to 80 Watt iron where someone with less
experience could overheat and damage the PCB foil.
Hot Air Desoldering Tool
Temperature: 608 F ± 68 F (320 C ± 20 C)
12.3.2. Caution
To replace the IC efficiently, choose the right sized nozzle of the hot air desoldering tool that matches the IC package.
Be careful about the temperature of the hot air desoldering tool not to damage the PCB and/or IC.
12.3.3. How to Remove the IC
1. Heat the IC with a hot air desoldering tool through the
P.C.Board.
2. Pick up the IC with tweezers, etc. when the solder is
melted completely.
Note:
Be careful not to touch the peripheral parts with twee-
zers, etc. They are unstable.
3. After removing the IC, clean the P.C.Board of residual sol-
der.
12.3.4. How to Install the IC
1. Place the solder a little on the land where the radiation
GND pad on IC bottom is to be attached.
2. Place the solder a little on the land where IC pins are to
be attached, then place the IC.
Note:
When placing the IC, the positioning should be done very
carefully.
3. Heat the IC with a hot air desoldering tool through the
P.C.Board until the solder on IC bottom is melted.
Note:
Be sure to place it precisely, controlling the air volume of
the hot air desoldering tool.
4. After soldering, confirm there are no short and open cir-
cuits with visual inspection.

Table of Contents