Items
Adjustment 
Point
Procedure Check 
Repla
Part
(M
)*
RSSI Level 
Confirmation
- Follow steps 1 to 3 of (H) above. 
4. Set DECT tester power to -88dBm.
5. Execute the command "readrssi".
6. Confirm: 29 < returned value < 3E (hex)
IC2, I
L1,
C43, C
C75
C69, C
C72
C66, C
C76
C57, C
L3,
DA1, R
R67
C55, C
R78
R79, C
C58
C86, 
(N
)*
Receive Audio 
Check and 
Adjustment
ANT 
J1
1. Configure the DECT tester (CMD60) as follows;
<Setting>
-Test mode: FP
-Mode: Normal
-PMID: 0000
2. Execute the command "testmode".
3. Initiate connection from DECT tester.
4. Execute the command "hookoff".
5. Execute the command "openau".
6. Connect J1 (Telephone Socket) to Tel-simulator which is connected with 600  
 .
7. Set line voltage to 48V and line current to 40mA.
8. Connect DECT tester to Tel-simulator.
9. Input audio signal (200mVrms/1kHz tone) to Tel-simulator.
<DECT tester setting>
-Scramble: On
-AF Gen to ADPCM: Off
-AF Meter Input: ADPCM
-AF Gen Frequency: 1000Hz
-AF Gen Level: 200mVrms
10. Confirm hearing tone: 300mVrms ± 100mVrms
11. Adjust audio level if required. (Make sure current value using "getmicgain". And 
then execute the command "setmicgain xx", where xx is the value.)
12. Confirm that the B-field audio distortion with DECT tester is < 5 %.
IC2, C
R31
C20, C
R18
R16, 
R12
Q2, R7, 
 
Q3, R
R10
D2, C1, 
 
R77, I
L1,
C43, C
C75
C69, C
C72
C66, C
C76
C57, C
L3,
DA1, R
R67
C55, C
R78
R79, C
C58
C86, 
42
www.freeservicemanuals.info
Digitized in Heiloo, Holland