System Outline 1-9
1.5 Specifications
1.5.1 General Description
System Capacity KX-TD816
CO lines (ISDN S0 lines) 8 max. (2 max.)
Extensions 16 max. (32 max. with XDP)
KX-TD1232
CO lines (ISDN S0 lines) 12 max. (6 max.)
Extensions 32 max. (64 max. with XDP)
Control Method Stored Program CPU: 16 bits CPU
Switching Non Blocking PCM Time Sharing Switch
Power Supplies Primary 240 VAC, 50Hz
Secondary Station Supply Volt: 30V
Circuit Volt: ± 5V, ± 15V
Power Failure Memory back-up duration: seven years
by factory-provided lithium battery
3 CO lines max. automatically assigned
to SLTs (Power Failure Transfer)
System operation for several hours by
recommended batteries (consisting of two
12 VDC car batteries)
Dialing Outward Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialing
Internal Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialing
Mode Conversion DP-DTMF, DTMF-DP
Connector KX-TD816
CO lines Modular jack
Extensions Modular jack
KX-TD1232
CO lines 4-pin connector
Extensions Amphenol connector
Paging Output Pin Jack (RCA JACK)
External Music Input Two-conductors Jack
(MINIJACK 3.5 mm diameter)