EasyManua.ls Logo

Panasonic KX-TD816AL - Page 64

Panasonic KX-TD816AL
377 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation 2-37
2.4.3 Lightning Protector Installation
Earth Rod Installation Diagram
The length of earth rod and the required depth depend on the
composition of the soil. Consider the following recommendations:
1) Installation location of the earth rod.............Near the protector
2) Check obstructions........................................None
3) Composition of the earth rod........................Metal
4) Depth of the earth rod...................................More than 50 cm
5) Size of the earth wire....................................Thickness is more
than 1.6 mm
Main
Unit
CO
Lightning
Protector
Earth Wire
(Underground)
Earth Rod

Table of Contents