Switch to control normal mode and test modes on this BU Test Fixture.
Test Fixture has two mode.
1. TEST mode: (RF Power Low mode)
The switch of Test Fixture changed with TEST mode side.
Then Test Fixture is in TEST mode.
2. Normal mode: (RF Power Normal mode)
The switch of Test Fixture changed with TEST mode side.
Then Test Fixture is in Normal mode.
NOTE:
Audio is coming from Receiver whether switch is inserted or not.
This test simulates the handset is at very large distance from the base unit and the TX signal
from base to handset is very small.
Procedure: First, place handset under test to charge (exchange security code), then remove
handset from base after you hear a beep. Press TALK button on handset and if it links with the
base, then this handset sensitivity is OK. If a beep is not heand, Replace the RF unit.
NOTE:
1) Only KX-TG2583/2563/2553/2403 with marks BU Test Fixture can be used for troubleshooting.
Regular KX-TG2583/2563/2553/2403 production samples does not have the software needed for
troubleshooting.
43