Economy Auto Fan Speed O O
Sleep Shift O
MODE JUDGEMENT O
8.10. Airflow Direction Control
1. Vertical Airflow Direction
Cooling and Soft Dry Mode
- The louver swings up and down as shown above.
- The louver does not swing when the Indoor Fan stops during
operation.
2. Vertical Airflow Direction
Heating Mode
- When the intake air temp. reaches 38°C, the louver is changed
from upper to lower limit. When the intake air temp falls to
35°C, the louver is changed from lower to upper limit.