Air Volume Indoor Air (Lo)
m
3
/min
(cfm)
Cooling; 6.8 (240) - 6.0
(210)
—
Heating; 6.8 (240) - 6.0
(210)
Indoor Air (Me)
m
3
/min
(cfm)
Cooling; 8.0 (280) - 7.1
(250)
—
Heating; 8.0 (280) - 7.1
(250)
Indoor Air (Hi)
m
3
/min
(cfm)
Cooling; 9.4 (330) - 8.9
(310)
—
Heating; 9.9 (350) - 9.7
(340)
Indoor Air (SHi)
m
3
/min
(cfm)
Cooling; 9.9 (350) - 9.6
(340)
—
Heating; 9.9 (350) - 9.7
(340)
dB (A) Cooling; High 39-38, Low
28-26
Cooling;
Heating; High 39-39, Low
28-26
Heating;
Noise Level
Power level
(dB)
Cooling; High 52-50, Low
40-38
Cooling;
Heating; High 52-52, Low
41-38
Heating;
Electrical Data Input W Cooling; 970 - 920
Heating; 910 - 840
Running Current A Cooling; 4.3 - 4.3
Heating; 4.0 - 3.9
EER W/W (BTU/
hW)
Cooling; 2.73 - 2.83 (9.3 - 9.6)
COP W/W (BTU/
hW)
Heating; 3.52 - 3.69 (12.0 -
Starting Current A 16.4
7