Error Display
The buzzer sounds and “U”/“H” and a number are alternately displayed.
Cancel Child Lock (P. 11) if it is set.
Error display Points to be checked
Water cannot drain.
Check the drain water hose for the following abnormalities:
Is it crushed?
Is it clogged with lint?
Is the hose tip under water?
Is it partially raised higher than 10
cm above the oor? (P. 14)
Is the total length longer than 3
m (including the extension hose)? (P. 14)
When the above problems are solved, you can resume operation by opening and
closing the lid.
The lid is open.
Did you try to run the washing machine with the lid open?
→Close the lid.
Spin or Air Dry is not possible.
Are clothes concentrated on one side of the tub?
→Distribute the clothes evenly and close the lid.
Is the washing machine installed on an unstable
or inclined surface?
You can resume operation by opening and
closing the lid.
Water cannot be supplied.
Is the water faucet turned on?
→When using Temp Setting, Collar/Cuff, Oil and Curry programs, turn on both hot
and cold water faucets.
Water outage?
Is the water supply lter clogged with dirt? (P. 13)
→You can resume operation by opening and closing the lid.
Water has been forcibly drained.
Water has been forcibly drained because the lid was open for 10
seconds or more
with Child Lock (P. 11) set.
Unplug the power cord and plug it in again after 5
seconds.
Inspection is required.
Turn off the water faucet just to be safe. Then, report the error displayed (2-digit
number after “H”) to a service person. Unplug the power cord.
Hot /
Warm
lamp
(P. 4)
Flashing
Normal operation
(The lamp ashes only during hot water supply.)
Flashing
quickly
The hot water faucet is not turned on / not connected.
The washing machine operates using cold water.
(May cause less washing performance)
The lamp continues ashing during operation or for 8 hours after operation until
the lid is opened.