Items Commands:Parameters Functions Callback Remarks
ENTER OEN ENTER key OEN
CURSOR OCU UP key OCU
OCD DOWN key OCD
OCL LEFT key OCL
OCR RIGHT key OCR
STANDARD OST STANDARD key OST
AUTO SETUP OAS AUTO SETUP execution OAS
SHUTTER OSH:0 SHUTTER key
0=OFF 1=ON
OSH:0 Calls back ER402 when
SHUTTER of REMOTE2 is ON.
OSH:1 OSH:1 Calls back ER402 when
SHUTTER of REMOTE2 is OFF.
INPUT SELECT IIS:RG1 RGB1 IIS:RG1 Calls back ER402 if the
input switch of REMOTE2 is
available.
IIS:RG2 RGB2 IIS:RG2
IIS:VID VIDEO IIS:VID
IIS:SVD S-VIDEO IIS:SVD
IIS:DVI DVI IIS:DVI
FUNCTION1 FC1 FUNC1 key FC1
ON SCREEN OOS:0 OSD selection
0= OSD OFF 1=OSD ON
OOS:0 Effective and invalidity
are the same as remote
control OSD key.
OOS:1 OOS:1
NUMBER KEY ONK:0 NUMBER key 0 ONK:0
ONK:1 NUMBER key 1 ONK:1
ONK:2 NUMBER key 2 ONK:2
ONK:3 NUMBER key 3 ONK:3
ONK:4 NUMBER key 4 ONK:4
ONK:5 NUMBER key 5 ONK:5
ONK:6 NUMBER key 6 ONK:6
ONK:7 NUMBER key 7 ONK:7
ONK:8 NUMBER key 8 ONK:8
ONK:9 NUMBER key 9 ONK:9
SYSTEM SEL OSL SYSTEM SELECTER key OSL
5.6.2. Data setting Commands
Items Commands:Parameters Functions Callback Remarks
PICTURE MODE VPM:NAT Sets to NATURAL. VPM:NAT
VPM:STD Sets to STANDARD. VPM:STD
VPM:DYN Sets to DYNAMIC. VPM:DYN
VPM:CIN Sets to CINEMA. VPM:CIN
VPM:GRA Sets to GRAPHIC. VPM:GRA
TV-SYSTEM VSG:AT1 Sets to AUTO1. VSG:AT1 Calls back ER401 when
receiving the signal
that cannot be
switched.
VSG:AT2 Sets to AUTO2. VSG:AT2
VSG:NTS Sets to NTSC. VSG:NTS
VSG:N44 Sets to NTSC4.43. VSG:N44
VSG:PAL Sets to PAL. VSG:PAL
VSG:PAN Sets to N-PAL. VSG:PAN
VSG:PAM Sets to M-PAL. VSG:PAM
VSG:SEC Sets to SECAM. VSG:SEC
VSG:P60 Sets to PAL60. VSG:P60
RGB/YPbPr
SELECT
ORF:0 Sets to RGB. ORF:0 Calls back ER401 when
receiving the signal
that cannot be
switched.
ORF:1 Sets to YPbPr/YCbCr. ORF:1
ORF:2 Sets to AUTO. ORF:2
ASPECT VSE:0 Sets to AUTO. VSE:0 Calls back ER401 when
receiving the signal
that cannot be
switched.
VSE:1 Sets to 4:3. VSE:1
VSE:2 Sets to 16:9. VSE:2
VSE:3 Sets to S4:3. VSE:3
VOLUME AVL:p1p2p3 Volume control AVL:p1p2p3 p1p2p3: 000-063
MUTE AMT:0 Sets to OFF. AMT:0 Calls back AMT:0 when
REMOTE2 is effective
and SHUTTER is OFF.
Calls back ER402 when
REMOTE2 is effective
and SHUTTER is ON.
AMT:1 Sets to ON. AMT:1 Calls back ER402 when
REMOTE2 is effective
and SHUTTER is OFF.
Calls back AMT:1 when
REMOTE2 is effective
and SHUTTER is ON.
CONTRAST MODE VCR:0 Sets to STANDARD. VCR:0
VCR:1 Sets to HIGH. VCR:1
LAMP POWER OLP:0 LAMP POWER setting
0=HIGH 1=LOW
OLP:0 Available in STANDBY
Calls back ER402 when
Long Life Lamp is
used.
OLP:1 OLP:1