4/80
2. Basic Control Command
Explanatory notes
Yes: Enable
No: Disable
Limited: Refer to the note.
2.1. Power ON (Lamp ON)
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 50h 4Fh 4Eh 03h
Character A D Z Z ; P O N
Response (Callback)
In the period when the command can be accepted (This command in power-on condition is included.)
Hexadecimal 02h 50h 4Fh 4Eh 03h
Character P O N
Acceptability
SECURITY STNDBY ECO STNDBY NO SIGNAL SHUTTER FREEZE TEST PATTERN REMOTE2
Yes Ye s Yes Yes Ye s Yes Yes Limit ed
Notes:
- When you confirm whether to have succeeded in power-on, confirm it by QPW (Query Power) command after
receiving the callback of PON command.
- REMOTE2 is given to priority. Calls back ER401 when the parameter is different from the setting of REMOTE2.
2.2. Power OFF (Standby)
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 50h 4Fh 46h 03h
Character A D Z Z ; P O F
Response (Callback)
In the period when the command can be accepted (This command in power-off condition is included.)
Hexadecimal 02h 50h 4Fh 46h 03h
Character P O F
Acceptability
SECURITY STNDBY ECO STNDBY NO SIGNAL SHUTTER FREEZE TEST PATTERN REMOTE2
Yes Ye s Yes Yes Ye s Yes Yes Li mit ed
Notes:
- When you confirm whether to have succeeded in power-off, confirm it by QPW (Query Power) command after
receiving the callback of POF command.
- REMOTE2 is given to priority. Calls back ER401 when the parameter is different from the setting of REMOTE2.
2.3. FREEZE
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 46h 5Ah 3Ah *1 03h
Character A D Z Z ; O F Z : *2
Parameters (*1, *2)
Freeze OFF Freeze ON
Hexadecimal 30h 31h
Character 0 1
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 46h 5Ah 3Ah *1 03h
Character O F Z : *2
Acceptability
SECURITY STNDBY ECO STNDBY NO SIGNAL SHUTTER FREEZE TEST PATTERN REMOTE2
No No No No No Yes Yes Yes
2.4. AUTO SETUP
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 41h 53h 03h
Character A D Z Z ; O A S
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 41h 53h 03h
Character O A S
Acceptability
SECURITY STNDBY ECO STNDBY NO SIGNAL SHUTTER FREEZE TEST PATTERN REMOTE2
No No No No No Yes No Yes
Note:
- This command is acceptable only when analog RGB/DVI signals (except a part of high dot clock signals) are input.
In other cases, ER401 is returned.