76/80
Parameters (*3, *4, *5, *6, ..., *41, *42, *43, *44)
Query Runtime (QFI:0)
Example: When the runtime time is 8 000 h
Hexadecimal 20h 38h 30h 30h 30h
Character 8 0 0 0
Query Rewinding number of times (QFI:1)
0 1 2
Hexadecimal 20h 30h 20h 31h 20h 32h
Character 0 1 2
10 11 12
Hexadecimal 31h 30h 31h 31h 31h 32h
Character 1 0 1 1 1 2
Query Filter kind (QFI:2)
Normal Smoke Not installed
Hexadecimal 30h 31h 32h
Character 0 1 2
Query Rewinding interval (QFI:3)
500 h 3000 h
Hexadecimal 30h 31h
Character 0 1
Query Elapsed time after rewinding (QFI:4)
Example: When the elapsed time after rewinding is 1 500 h
Hexadecimal 31h 35h 30h 30h
Character 1 5 0 0
Query Remaining time (QFI:5)
Example: When the remaining time is 4 500 h
Hexadecimal 20h 34h 35h 30h 30h
Character 4 5 0 0
Query Remaining percentage (QFI:6)
0 1 2
Hexadecimal 20h 20h 30h 20h 20h 31h 20h 02h 32h
Character 0 1 2
98 99 100
Hexadecimal 20h 39h 38h 20h 39h 39h 31h 30h 30h
Character 9 8 9 9 1 0 0
Note:
- When the remaining time is 10 000 h or more, 10000 is always returned as a response of the query.
2.202. Query STANDBY MODE
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 56h 58h 3Ah
Character A D Z Z ; Q V X :
Hexadecimal 53h 54h 4Dh 49h 30h 03h
Character S T M I 0
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 53h 54h 4Dh 49h 30h 3Dh 2Bh *1 *3
Character S T M I 0 = + *2 *4
Hexadecimal *5 *7 *9 03h
Character *6 *8 *10
Acceptability
SECURITY STNDBY ECO STNDBY NO SIGNAL SHUTTER FREEZE TEST PATTERN REMOTE2
Yes Ye s Yes Yes Ye s Yes Yes Yes
Parameters (*1, *2, *3, *4, *5, *6, *7, *8, *9, *10)
NORMAL ECO
Hexadecimal 30h 30h 30h 30h 30h 30h 30h 30h 30h 33h
Character 0 0 0 0 0 0 0 0 0 3