77/80
2.203. Query MAIN VERSION
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 56h 58h 3Ah
Character A D Z Z ; Q V X :
Hexadecimal 53h 56h 52h 53h 30h 03h
Character S V R S 0
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 53h 54h 4Dh 49h 30h 3Dh *1 *3 *5
Character S T M I 0 = *2 *4 *6
Hexadecimal *7 *9 *11 03h
Character *8 *10 *12
Acceptability
SECURITY STNDBY ECO STNDBY NO SIGNAL SHUTTER FREEZE TEST PATTERN REMOTE2
Yes Ye s Yes Yes Ye s Yes Yes Yes
Parameters (*1, *2, *3, *4, *5, *6, *7, *8, *9, *10, *11, *12)
Example: When the main CPU software version is 1.00.00
Hexadecimal 30h 31h 30h 30h 30h 30h
Character 0 1 0 0 0 0
2.204. Query SUB VERSION
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 56h 58h 3Ah
Character A D Z Z ; Q V X :
Hexadecimal 53h 56h 52h 53h 32h 03h
Character S V R S 2
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 53h 54h 4Dh 49h 32h 3Dh *1 *3 *5
Character S T M I 2 = *2 *4 *6
Hexadecimal *7 *9 *11 03h
Character *8 *10 *12
Acceptability
SECURITY STNDBY ECO STNDBY NO SIGNAL SHUTTER FREEZE TEST PATTERN REMOTE2
Yes Ye s Yes Yes Ye s Yes Yes Yes
Parameters (*1, *2, *3, *4, *5, *6, *7, *8, *9, *10, *11, *12)
Example: When the sub CPU software version is 1.00.00
Hexadecimal 30h 31h 30h 30h 30h 30h
Character 0 1 0 0 0 0
2.205. Query NETWORK VERSION
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 56h 58h 3Ah
Character A D Z Z ; Q V X :
Hexadecimal 53h 56h 52h 53h 31h 03h
Character S V R S 1
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 53h 54h 4Dh 49h 31h 3Dh *1 *3 *5
Character S T M I 1 = *2 *4 *6
Hexadecimal *7 *9 *11 03h
Character *8 *10 *12
Acceptability
SECURITY STNDBY ECO STNDBY NO SIGNAL SHUTTER FREEZE TEST PATTERN REMOTE2
Yes Ye s Yes Yes Ye s Yes Yes Yes
Parameters (*1, *2, *3, *4, *5, *6, *7, *8, *9, *10, *11, *12)
Example: When the network CPU software version is 1.00.00
Hexadecimal 30h 31h 30h 30h 30h 30h
Character 0 1 0 0 0 0