-12-
Maintenance
5) Clean the air filter unit.
ò
Removing the dust from the air filter unit
(i) Remove the dust from the air filter unit using a vacuum or other cleaner.
•Ifthedustpersistsaftercleaningwithavacuum,washtheairfilterunitinwater.
ò
Washing the air filter unit
(i) Soak the air filter unit in water or warm water and rinse it lightly.
•Donotusematerialssuchasblushesordetergent.
•Whenyourinsetheairfilterunit,holdtheframeandavoidexcessiveforceonthefilterpart.
(ii) Change the water two or three times while you rinse the air filter unit.
•Rinseituntilthecloudofthewaterclears.Iftheairfilterunitisnotrinsedsufficiently,odormayresult.
ò
Drying the air filter unit
Naturally dry the air filter unit in a well-ventilated place, avoiding dust and direct sunlight.
•Donotuseahairdrierorotherdrier.
6) Attach the air filter unit.
ò
Hold the air filter unit that the tab is in left side in the figure. put the right side in the figure first, and press the
tab side until make a click sound.
7) Close and press up to lock the filter cover.
ò
Make sure that the air filter cover is closed tightly.
8) Reset the filter counter.
ò
Turn on the power and perform [Filter counter reset] in the [Setting] menu.
Attention
ò
After washing the air filter unit, dry it thoroughly before attaching to the projector. Attaching wet air filter may
cause electric shock or malfunction.
Note
ò
Be sure to attach the air filter unit properly. If you use the projector without attaching the air filter unit, the projec-
tor may be damaged due to the dirt or dust.
ò
If the air filter unit has been damaged or dirt remains even after washing it, replace it with a a new filter.
ò
It is recommended that the air filter unit is replaced after two times of cleaning and reusing.
ò
After washing, the capability of the air filter unit may decrease.
ò
After washing the air filter unit, reset the filter counter. Otherwise, the power of the projector may be turned off