Using WebBrowser (cont.)
Example of email message sent
If [NORMAL] is selected under [MAIL CONTENTS]
A If you have completed the email settings B If an error occurs
If [SIMPLE] is selected under [MAIL CONTENTS]
C If you have completed the email settings D If an error occurs
=== Panasonic projector report(CONFIGURE) ===
Projector Type  : F300NT
-----  E-mail setup data -----
TEMPERATURE WARNING SETUP 
MINIMUM TIME  at [ 60] minutes interval 
INPUT AIR TEMPERATURE  Over [ 32C / 89F ] 
ERROR  [ ON  ] 
LAMP RUNTIME  [ ON  ]  at REMAIN [ 400] H 
LAMP RUNTIME  [ ON  ]  at REMAIN [ 200] H 
FILTER REMAIN  [ ON  ]  at REMAIN [ 500] H 
FILTER REMAIN  [ ON  ]  at REMAIN [  0] H 
INPUT AIR TEMPERATURE  [ ON  ] 
PERIODIC REPORT 
Sunday  [ ON  ]  Monday  [ ON  ]  Tuesday  [ ON  ]  Wednesday [ ON  ] 
Thursday  [ ON  ]  Friday  [ ON  ]  Saturday  [ ON  ] 
00:00  [ ON  ]  01:00  [ ON  ]  02:00  [ ON  ]  03:00  [ ON  ] 
04:00  [ ON  ]  05:00  [ ON  ]  06:00  [ ON  ]  07:00  [ ON  ] 
08:00  [ ON  ]  09:00  [ ON  ]  10:00  [ ON  ]  11:00  [ ON  ] 
12:00  [ ON  ]  13:00  [ ON  ]  14:00  [ ON  ]  15:00  [ ON  ] 
16:00  [ ON  ]  17:00  [ ON  ]  18:00  [ ON  ]  19:00  [ ON  ] 
20:00  [ ON  ]  21:00  [ ON  ]  22:00  [ ON  ]  23:00  [ ON  ] 
-----  check system -----
MAIN CPU BUS    [  OK 
FAN        [  OK 
INPUT AIR TEMPERATURE  [  OK 
OUTPUT AIR TEMPERATURE  [  OK 
LAMP REMAIN TIME    [  OK 
LAMP STATUS     [  OK 
INPUT AIR TEMP.SENSOR  [  OK 
OUTPUT AIR TEMP.SENSOR  [  OK 
BATTERY      [  OK 
ACF UNIT      [  OK 
FILTER REMAIN  [  OK 
(Error code 00 00 00 00 00 00 00 00)
Input air temperature  :-44 degC / -47 degF
Output air temperature  : 30 degC /  86 degF
SET RUNTIME   188 H
POWER ON      0 times
LAMP  ON     21 times
LAMP  HIGH     30 H
LAMP  REMAIN     4970 H
FILTER REMAIN    0 H
-------- Current status ---------
MAIN VERSION  1.00.0 
NETWORK VERSION  1.00 
LAMP STATUS  LAMP=OFF
INPUT SIGNAL  NETWORK  ---
  ---kHz / ---Hz
REMOTE2 STATUS  DISABLE 
----- Wired Network configuration -----
DHCP Client  OFF 
IP address  10.69.104.183
MAC address  00:40:63:00:00:12
----- Wireless Network configuration -----
IP address  169.254.213.197
MAC address  00:0E:10:02:6E:7E
Wed Sep 17 13:45:42 2008
----- Memo -----
[
F300NT
]
=== Panasonic projector report(ERROR) ===
Projector Type          : FW300NTU
-----  check system -----
MAIN CPU BUS                  [ FAILED ]
FAN                           [   OK   ]
INPUT AIR TEMPERATURE         [   OK   ]
OUTPUT AIR TEMPERATURE        [   OK   ]
LAMP REMAIN TIME              [   OK   ]
LAMP STATUS                   [ FAILED ]
INPUT AIR TEMP.SENSOR         [ FAILED ]
OUTPUT AIR TEMP.SENSOR        [   OK   ]
BATTERY                       [   OK   ]
ACF UNIT                      [ FAILED ]
FILTER REMAIN                 [   OK   ]
(Error code 84 44 00 00 10 00 00 04)
Input air temperature      :-44 degC / -47 degF
Output air temperature     : 29 degC /  84 degF
SET RUNTIME       194 H
LAMP  ON           21 times
LAMP  HIGH         36 H
LAMP  REMAIN     4964 H
------- Remaining filter --------
QUANTITY            0 %
APPOROX. TIME       0 H
-------- Current status ---------
MAIN VERSION         1.00.0
NETWORK VERSION      1.000
LAMP STATUS          LAMP=OFF
INPUT SIGNAL         NETWORK   ---
                     ---kHz / ---Hz
REMOTE2 STATUS       DISABLE 
----- Wired Network configuration -----
DHCP Client  OFF 
IP address   10.69.104.183
MAC address  00:40:63:00:00:12
----- Wireless Network configuration -----
IP address   169.254.213.197
MAC address  00:0E:10:02:6E:7E
Wed Sep 17 13:45:42 2008
----- Memo -----
[
F300NT
]