-51-
Electrical Adjustments
Group/
Item
Item Name Function Initial Range Note
Group
253
Fan Temp Error Setting
(Memorized)
Normal
(OFF)
Ceiling
(OFF)
HiLand
Normal
(ON1/
ON2)
HiLand
Ceiling
(ON1/
ON2)
5 Temp A Warning (Normal) 43 43 0/40 0/40 30 - 100
6 Temp B Warning (Normal) 52 52 0/52 0/52 30 - 100
7
Temp C Warning (Nor-
mal)
60 60 0/55 0/55 30 - 100
8
Temp B-A Warning
(Normal)
100 100 100/100 100/100 0 - 100
9
Temp C-A Warning
(Normal)
100 100 100/100 100/100 0 - 100
10 Temp A Warning (Eco)
Temp. A to judge the Temp Error
at Normal (Room)
42 42 0/40 0/40 30-100
11 Temp B Warning (Eco)
Temp. B to judge the Temp Error
at Normal (Panel)
54 54 0/50 0/50 -
12 Temp C Warning (Eco)
Temp. C to judge the Temp Error
at Normal (Lamp)
60 60 0/52 0/52 30-100
13 Temp B-A Warning (Eco)
Temp. B-A to judge the Temp
Error at Normal (Clogging Det.)
100 100
100/100 100/100
0-100
14 Temp C-A Warning (Eco)
Temp. C-A to judge the Temp
Error at Normal (Clogging Det.)
100 100
100/100 100/100
0-100
15
Temp A Warning Offset
(Temp)
Offset of Temp Error (Temp.)
Error Setting Value is increased
XC at the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp
mode
5 0-100
16
Temp B Warning Offset
(Temp)
5 0-100
17
Temp C Warning Offset
(Temp)
10 0-100
18
Temp B-A Warning Offset
(Temp)
0 0-100
19
Temp C-A Warning Offset
(Temp)
0 0-100
20
Temp A Warning Offset
(Time)
Offset of Temp Error (Minutes)
Error Setting Value is increased
X minute at the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp
mode
3 0-5
21
Temp B Warning Offset
(Time)
3 0-5
22
Temp C Warning Offset
(Time)
3 0-5
23
Temp B-A Warning Offset
(Time)
3 0-5
24
Temp C-A Warning Offset
(Time)
3 0-5
Group
254
Fan Control Range Setting (Temp./Voltage)
Normal
(OFF)
Ceiling
(OFF)
Hiland
Normal
(ON1 DIF/
ON2)
Hiland
Ceiling
(ON1 DIF/
ON2)
10
High Fan Control Min
Temp
35 35 0/32 0/32 20 - 100
11
High Fan Control Max
Temp
40 40 0/38 0/38 20 - 100
12 High Fan1 Min 65 65 -10/125 -10/125 0 - 255
13 High Fan1 Max 135 135 0/135 0/135 0 - 255
14 High Fan2 Min 65 65 -10/90 -10/90 0 - 255
15 High Fan2 Max 120 120 0/135 0/135 0 - 255
16 High Fan3 Min 77 77 -5/85 -5/85 0 - 255
17 High Fan3 Max 90 90 -5/100 -5/100 0 - 255
20
Eco Fan Control Min
Temp
Temp Senser Control Start/End
Tem.p at Eco
36 36 0/32 0/32 20-100
21
Eco Fan Control Max
Temp
39 39 0/38 0/38 20-100
22 Eco Fan1 Min
Fan voltage value at Eco (unit:
0.1V)
45 45 -10/110 -10/110 0-255
23 Eco Fan1 Max 120 120
0/120 0/120
0-255
24 Eco Fan2 Min 50 50 -10/85 -10/85 0-255
25 Eco Fan2 Max 100 100
0/100 0/100
0-255
26 Eco Fan3 Min 55 55 -5/60 -5/60 0-255
27 Eco Fan3 Max 65 65 -5/80 -5/80 0-255
Group
255
Fan Start/Cooling Setting
0 Fan1 Initial Volt
Fan Start Voltage (0.1V)
50 0-255
1 Fan2 Initial Volt 50 0-255
2 Fan3 Initial Volt Fan Start Voltage (0.1V) 50 0-255
4 Fan1 Cooling Speed Power off :Fan Voltage(0.1V) 45 0-255
5 Fan2 Cooling Speed Power off :Fan Voltage(0.1V) 60 0-255
6 Fan3 Cooling Speed Power off :Fan Voltage(0.1V) 135 0-255
8 Cooling Time L1
Cooling Time setting at Fan
Mode L1 (x 30 sec)
1: 30, 3: 90, 15: 450 sec.
2 1-15
9 Cooling Time L2
Cooling Time setting at Fan
Mode L2 (x 30 sec)
1: 30, 3: 90, 15: 450 sec.
3 1-15