EasyManua.ls Logo

Panasonic PT-TX400

Panasonic PT-TX400
104 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
56 - ENGLISH
Note
f It is set to [Off] when using the projector in the elevation of below 1 400 m (4 593’). It is set to [On] when using the projector
in the elevation of above 1 400 m (4 593’) and below 2 700 m (8 858’). Failure to do so may shorten the life of the internal
parts and result in malfunctions.
f Do not set the projector in the elevation of 2 700 m (8 858’) or above, otherwise it may shorten the life of the internal parts
and result in malfunctions.
f When it is set to [On], the fan noise becomes louder and fan speed increases.
[Lamp control]
Switch the brightness of the lamp according to the operating environment of the projector or the purpose.
1) Press as to select [Lamp control].
2) Press the <ENTER> button.
3) Press as to switch the item.
f The items will switch each time you press the button.
f You can also press the <LAMP> button on the remote control. (x page 41)
[ (Normal)]
Select when high luminance is required.
[
(Eco 1)]
Select when high luminance is not required.
[
(Eco 2)] Select when lower luminance than [ (Eco 1)] is required.
Note
f Set it to [ (Eco 2)] rather than [ (Eco 1)], set it to [ (Eco 1)] rather than [ (Normal)], when you want to reduce
power consumption, extend the life of lamp and reduce operation noise.
[Cooling fast]
Switch the cooling fan' speed when the power is turned off and shorten the cooling time of the cooling fan.
1) Press as to select [Cooling fast].
2) Press the <ENTER> button.
3) Press as to switch the item.
f The items will switch each time you press the button.
[Normal] Use this setting normally.
[60 Sec] Use this setting when short cooling period of time is required.
[0 Sec] The cooling fans stop immediately after power-off.
Note
f When it is set to [0 sec], you cannot restart the projector immediately after the power-off. The lamp remains high temperature
and needs to be cooled, so it sometimes takes longer time than usual for the lamp to light up again.
f When it is set to [60 sec], the cooling fans' speed is faster and the motor noise is louder than [Normal] setting after the
power-off.
[Closed caption]
(Only for NTSC input)
Set the closed caption.
1) Press as to select [Closed caption].
2) Press the <ENTER> button.
3) Press as to switch the item.
f The items will switch each time you press the button.
[Off] Closed caption is not displayed.
[CC1] Displays CC1 data.
[CC2] Displays CC2 data.
[CC3] Displays CC3 data.
[CC4] Displays CC4 data.
Note
f Closed caption is a function that displays text information of video signals mainly used in North America. Captions may not
be displayed depending on the connected devices or contents being played back.
Chapter 4 Settings - [Setting] menu

Table of Contents

Related product manuals