25.2.5 Abnormal Solar Sensor (- / - / H28)
Malfunction Caused:
1 Faulty connector connection.
2 Faulty solar sensor.
3 Faulty indoor sub PCB.
Abnormality Judgment:
Continue for 5 seconds.
For safety reason and to prevent
component breakdown, always switch
off the power before remove and
connect the component.
YES
Correct sensor connect ion
NO
YES
Abnormal solar sensor
H28 happens check connection at CN207 normal?
Change solar sensor
NO
Measure resistance of sensor match characteristic?
Change Indoor sub PCB