respective indication is displayed when " /-DEMO" button is
pressing repeatedly. (e.g. H01 CD F15 F01) / If no error is
found, only "TEST" indication is displayed and remains unchange
even if " /-DEMO" button is pressed.
5.5. Displaying Self-Diagnostic Results
<Cassette Deck Section> (H01, H02, H03, F01, F02)
1. Enter the self-diagnostic mode, following the instructions
described in [5.2. Entering Self-Diagnostic Mode].
2. Insert a normal-positioned music tape with erase prevention
niches on both Sides A and B. Press [TAPE ] button to activate
the TPS operation so that the tape automatically stops at an
interval between music selections.
3. Press [ /CLEAR] and [TAPE ] buttons together on the remote
controller. (Recording does not start.)
4. Then, insert a Cr02-positioned blank cassette tape with an erase
prevention niche of Side A or B set to the left side.
5. Press [ /FF/ ] button. The tape will be forwarded and
automatically stop after two seconds.
6. Remove the cassette tape, and set the other side.
7. Press [ /REW/ ] button. The tape will be rewound and
automatically stops after two seconds.
8. Press [ /-DEMO] button on the unit.
If an error is found, a self-diagnostic key appears on the display.
If several errors are found, the display shows these keys when [ /
-DEMO] button is pressed repeatedly. (Ex.: H01 - H02 - F01 - H01)
If no error is found, only the message, “CD TEST” appears on the
display.
(*1) TPS operation (music search) detects the blank sections between music selections.
Therefore, do not use tapes with the following conditions:
- A blank section that lasts only 4 seconds or less.
- No blank sections (recording through microphones, etc.).
- Music selections that have extremely low pitches or prolonged
8