15 No S-reel pulse when cassette is loaded
(Capstan system, S-reel system failure)
VCR mode S-reel pulse counting value Tape
position
None
16 Cylinder lock detected during normal rotation VCR mode Processing number Tape
position
None
17 S-reel lock detected during normal running VCR mode Processing number Tape
position
FG count
18 T-reel lock detected during normal running VCR mode Processing number Tape
position
FG count
80 EJECT mode when an error is detected VCR mode *1 Tape
position
None
2* Error during PG automatic adjustment VCR mode - Tape
position
None
(Meaning of Additional data, (Data 1), VCR mode)
0 : STOP, 1 : EJECT, 2 : REW 3 : FF, 4 : REV, 5 : CUE, 6 : SLOW 7 : POWER OFF, 8 : PLAY, 9 : STILL, U : REC, A : REC
PAUSE, - : ADUB, N : ADUB PAUSE, L : INSERT, NONE DISPLAYED : INSERT PAUSE
(Meaning of Additional data, (Data 2), Tape position)
Type of tape Criterion of tape position between starting and end terminals
T-90 or above (Thin Hub) Between starting terminal: L and end terminal: 1 with fourteen levels of change
T-60 or below (Thick Hub) Between starting terminal: U and end terminal: 5 with sic levels of change
(Data 2 display)
Thin Hub Ln--Au987654321
Thick Hub U98765
*1 (Additional data, (Data 2)) (EJECT reason)
Data 2 Reason
1 Loading completed when no tape is loaded. (spinning)
2 S-photo, S-reel, or Cap system failure during down short REW
operation
3 Mechanism locking during loading
4 L both terminals detected when loading starts
*Additional data 3 and 4
While the self-diagnosis history is displayed, press the STOP button (on the unit or the remote controller unit) to switch
between Additional data 3 and 4.
17