EasyManua.ls Logo

Panasonic SB-FS730

Panasonic SB-FS730
158 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Section Code Meaning Note
Microcomputer
error
F700 MBX overflow When replying a message to Disc Manager. (operation
continues)
F701 Message command incomplete A message is issued before replying to Disc Manager.
F702 Message command changed A message is issued before replying to Disc Manager.
F710 AD conversion at AN0 incomplete Conversion cannot be complete within a designated
time during check of AD conversion before Y/C
automatic adjustment.
F711 AD conversion at AN1 incomplete Conversion cannot be complete within a designated
time during check of AD conversion before Y/C
automatic adjustment.
F712 AD conversion at AN0 dispersed Conversion result exceeds standards while a
designated value is set during check of AD conversion
before Y/C automatic adjustment.
F713 AD conversion at AN1 dispersed Conversion result exceeds standards while a
designated value is set during check of AD conversion
before Y/C automatic adjustment.
F720 DA conversion at AN0 unchangeable Conversion result exceeds standards while a
designated value is set during check of AD conversion
before Y/C automatic adjustment.
F721 DA conversion at AN1 unchangeable Conversion result exceeds standards while a
designated value is set during check of AD conversion
before Y/C automatic adjustment.
F880 Unsuitable task number When a message arrives from not existing task (error
stops)
F890 A message is sent during AV task transmission During transmission of a message to AV task (error
stops)
F891 Unable to transmit a message to AV task When a message starts transmission to AV task (error
stops)
F893 FLASH ROM altered Content of FLASH ROM change
F894 EEPROM failure EEPROM Promlem
F895 PERR JMP MI SMUCH Firm device incompatible (non-conformant destination
value)
F896 PERR JMP NON Firm device incompatible (non existing jumper)
F897 PERR NO INIT Initialization incomplete
F8A0 Unsuitable message command When a message starts transmission to AV task (error
stops)
10.2.3. CR16 Mechanism Ageing Mode
To enter into ageing mode :
1. Enter self-diagnostic mode. (Doctor Mode)
2. Press [3] button on remote control. It enters into ageing mode. (See below for ageing process)
Ageing process
1. Tray 1 open.
2. It waits for one second (Note : Do not put any disc into the tray)
3. Tray 1 close.
4. TOC READ (Reading incomplete)
5. Tray 2 open & repeat process 1 to 4. (Process repeat until Tray 5)
6. Tray check.
7. Whole process complete (Counter on FL increase by 1)
Display Example : [00000T3OP] ...TRAY OPEN
[00000T3CL] ...TRAY CLOSE
[00000T3RE] ...TOC READING
[00000T3CH] ...TRAY CHANGING
Note : To exit ageing mode, press [POWER] button. The unit will power down. Do not unplug the power cord until FL display shows
BYE “. This is to avoid tray jam problem.
10.2.4. Clearing Of Error Code
1. Enter into self-diagnostic mode
2. Press & hold [STOP] for 5 secords or more.