2.1.1 LEAKAGE CURRENT COLD CHECK
TOP PREVIOUS NEXT
1. Unplug the AC cord and connect a jumper between the two prongs on the plug.
2. Measure the resistance value, with an ohmmeter, between the jumpered AC plug and each
exposed metallic cabinet part on the equipment such as screwheads, connectors, control shafts,
etc. When the exposed metallic part has a return path to thechassis,the reading should be between
1M and 5.2M.
When the exposed metal does not have a return path to the chassis, the reading must be
.
Figure 1
TOP PREVIOUS NEXT
file:///C|/Documents and Settings/lopez/Pulpit/s/PANASONIC SA-HT870E_EG_EB/ALL/SVC/s0201010000.html08-08-29 18:01:59