5. Mounting
CAUTION
Do not apply the load such as forced bending to the cable of this device. Applying im-
proper load could cause the wire breakage.
The minimum bending radius of the cable is R6mm. Mount the device with considering
the cable bending radius.
Mount the emitter and the receiver at the same level and parallel to each other. The effective aperture
angle of this device is ±2.5° or less at a sensing distance of 3m.
<In case of using standard mounting bracket MS-SFC-1 (accessory)>
Direction of the standard mounting bracket
MS-SFC-1
which is attached to this device
can be changed depending on the mounting position of the device.
1. Remove the M3 countersunk head screw [with anti-loosening agent (length 4mm)] which
is attached to the back of the device.
2 Decide the direction of the standard mounting bracket.
3. Tighten with the M3 countersunk head screw [with anti-loosening agent (length 4mm)].
The tightening torque should be 0.3N·m.
Install the standard mounting brackets in the mounting surface with two hexagon-socket
head bolts [M5 (purchase separately)].
<Reference>
Standard mounting bracket
MS-SFC-1
(Accessory)
M3 countersunk head screw
[With anti-loosening agent (length 4mm)]
This device
This device
Hexagon-socket head bolt
[M5 (Purchase separately)]