9.2.21. Remove the Cabinet assy from the
Plasma panel section
1. Place the Cabinet assy on a flat surface of a table
(covered by a soft cloth) and a cushion.
2. Remove the screws (×21 ).
3. Remove the Cabinet assy from the Plasma panel section.
9.2.22. Remove the Contact metals
1. Remove the screws (×10 ).
2. Remove the Contact metal side (L, R).
3. Remove the screws (×15 ).
4. Remove the Contact metal bottom A.
9.2.23. Remove the C1-Board
1. Disconnect the flexible cables (CB1, CB2, CB3, CB4 and
CB5).
2. Disconnect the flexible cable (C10).
3. Remove the screws (×4 ) and remove the C1-Board.
9.2.24. Remove the C2-Board
1. Disconnect the flexible cables (CB6, CB7, CB8, CB9,
CB10 and CB11).
2. Disconnect the flexible cables (C20, C26 and C27).
3. Disconnect the connector (C25).
4. Remove the screws (×4 ) and remove the C2-Board.