How to set Remocon User Level and Remote ID off
1.Access service mode (CAT-mode) and press SET UP key on remote.
2.Accsess Hidden option menu.
3.Change Remocon User Level and/ or Remote ID set to Off.
TOP PREVIOUS NEXT
Hidden Option Menu for GP6D series
Option menus default
setting
Contents
Off-timer function Enable Off-timer operation Enable/Disable.
On Screen display On Enable/Disable to display input mode indication after power on and no signal indication.
Initial Input Off Sets the initial input mode when the power is turned on . Allow input mode selection while power is on.
Initial VOL. level Off Sets the initial volume level when the power is turned on. Allow Volume control while power is on.
Maximum VOL.
Level
Off Sets the maximum volume to desired level. Volume cannot exceed this level.
INPUT lock Off Fixes the input mode to AV, Component/RGB or PC. Can not change input mode by input selection key.
Button lock Off Enable/Disable front operation buttons (Input and/or volume up/down)
Studio W/B Off Set warm mode color temperature to 3,200 Kelvin.
Remocon User Level Off Remote key invalidation.
Off : Valid key is all key of remote.
User1 : Valid key are only Stand-by (ON/OFF), Input, Status, Surround, Sound mute On/Off, and volume
adjustment.
User2: Valid key is only Stand-by (ON/OFF).
User3 : All keys are null and void
ID Select 0 to 100 Set ID number from 001 to 100.
Remote ID Off Remote ID function On/Off.
(While the Remote ID on, standard remote function can not control the unit.)
Serial Off Serial ID function On/Off
Slot power Off Sets the slot power mode the power is turned on.