TH-50PF20E / TH-50PF20ER
7 Troubleshooting Guide
7.1. Self Check
7.1.1. Display Indication
1. Self-check is used to automatically check the bus line
controlled circuit of the Plasma display.
2. To get into the Self-check mode, press the volume down
button on the customer controls at the bottom of the set,
at the same time pressing the OFF-TIMER button on the
remote control, and the screen will show.
If the IIC ports have been checked and found to be incorrect
Or not located then - - will appear in place of OK
01 in the line of the PTCT means the number of blinks of
the Power LED is 1. (Reference to 7.1.2)
H09 in the line of the PTCT is the error code.
To exit the CAT mode switch off the main power.
Note:
The line of the PTCT displays when you get into the Self
check mode for the first time only after the Power LED
blinks.