2. Disconnect the relay connector L, R.
3. Remove the Speaker L, R.
6.23. Remove the stand brackets.
1. Remove the plasma panel section from the servicing stand
and lay on a flat surface such as a table (covered), with the
plasma panel surface facing downward.
Spread a soft cloth or similar on the table for protection, so
the panel surface is not scratched.
2. Remove the stand bracket (left, right) fastening screws (×4
each) and remove the stand brackets (left, right).
6.24. Remove the C4-Board
1. Remove the flexible cables holder fastening screws (×8
) and disconnct the flexible cables (CB8, CB9, CB10
and CB11).
2. Release the speaker cables from clampers.
3. Disconnect the flexible cables (C41) and disconnect the
couplers (C42, C43 and C44).
4. Remove the screws (×5
) and remove the C4-Board.
16
TH-50PV500A / TH-50PV500H / TH-50PV500M