10.3. P.C.B. (Printed Circuit Board) exchange
10.3.1. Caution
1. To remove P.C.B. , wait 1 minute after power was off for discharge from electrolysis capacitors.
10.3.2. Quick adjustment after P.C.B. exchange
P.C.B. Name Test Point Voltage Volume Remarks
P Board Vsus TPVSUS (SS) Vsus ± 2V VR351 (P) *
SC Board Vad TPVAD (SC) -90V ± 1V VR6801(SC)
SS Board Ve TPVE (SS) Ve ± 1V VR6250 (SS) *
*See the Panel label.
10.4. Adjustment Volume Location
10.5. Test Point Location