41
English
Settings to connect to a LAN
[Important]
The network environment when controlling via LAN 
is required to be physically isolated from the outside 
network or not illegally connected / controlled by 
unknown equipment with the Firewall.
Set the display’s IP address and subnet mask to match 
the settings of your LAN.
These settings can be made on either the display or a 
computer connected to the display.
The settings depend on the configuration of your LAN. 
For instructions on connection, consult your network 
administrator.
To set on the display
Set [SERIAL IN/LAN select] of [Network settings] on the 
[Setup] menu to [LAN], and then set the [LAN setup] 
options. (see page 35)
After setting each item, select [Set] and press 
<ENTER>.
 ■ Network information
Displays LAN setting information. (see page 35)
 
Command-based control
You can control the display using serial commands (see 
page 20) via terminal software and other appropriate 
applications.
Read the manual for the terminal software for detailed 
instructions.
Supported commands
Commands used in the serial control are supported. 
(see page 20)
●
Default user name and password are as follows:
User name: dispadmin
Password: @Panasonic
If you change user name and password, please use the 
command below by serial line.
Command Parameter Control details
SSU:UNM *...* LAN control user name  
(Max 16 Parameters)
Range of parameters: 
[space] 0 1 2 3 4 5 6 7 8 9 A B C 
D E F G H I J K L M N O P Q R S 
T U V W X Y Z _ a b c d e f g h i j 
k l m n o p q r s t u v w x y z - @
SSU:UPW *...* LAN control password  
(Max 16 Parameters)
Range of parameters: 
[space] 0 1 2 3 4 5 6 7 8 9 A B C 
D E F G H I J K L M N O P Q R S 
T U V W X Y Z _ a b c d e f g h i j 
k l m n o p q r s t u v w x y z - @
1
Connect the computer to the display.
1. Specify the IP address and data port number 
(10101) and connect the computer to the display.
When connection has been established 
successfully, [Login:] is returned as response.
2. Send the user name.
●
Send [user name] + [ 
 ].
●
If the user name is not set, send [ 
 ].
●
When the transmission is successful, [ 
 
Password:] is returned as response.
3. Send the password.
●
Send [password] + [ 
 ].
●
If the password is not set, send [ 
 ].
●
When the transmission is successful, [OK 
 ] 
is returned as response.
2
Send commands to control the 
display.
The commands used are the same as those for 
RS-232C. Refer to the communication procedure 
(see page 20) for operation.
Usable commands are provided in the serial 
command table (see page 20).
3
Disconnect the connection with the 
display and quit the function.
●
Send [BYE 
 ]
When the transmission is successful, [goodbye] is 
returned and the connection is disconnected.
Note
●
The display automatically will disconnect one minute 
after receiving the last data without [BYE] command.
●
Repeating the procedure in 1 to 3 every time you 
send / receive a command or a group of commands 
is recommended for shortening the time for which the 
port is open .