Product name TK-CJ600 TK-CJ300
Dimensions (width × depth × height) 135 (W) × 120 (D) × 75 (H) mm 125 (W) × 110 (D) × 75 (H) mm
Weight
Approx. 350 g
(Approx. 490 g when full of water)
Approx. 310 g
(Approx. 450 g when full of water)
Water temperature when using the main
unit
Puried water: Under 35 °C (Unpuried/shower: Under 80 °C)
Minimum usable dynamic water pressure 70 kPa
Filtration ow volume 1.8 L / min [At water pressure 100 kPa]
Cartridge Installed In the unit TK-CJ600C-EX
Purication capacity
Free residual chlorine 4 000 L (*1)
Turbidity 4 000 L (*2)
Total trihalomethane 4 000 L (*1)
Bromodichloromethane 4 000 L (*1)
Dibromochloromethane 4 000 L (*1)
Bromoform 4 000 L (*1)
Tetrachloroethylene 4 000 L (*1)
Trichloroethylene 4 000 L (*1)
CAT (pesticide) 4 000 L (*1)
2-MIB (mold smell) 4 000 L (*1)
Soluble lead 4 000 L (*1)
Specications
Purication capacity
Benzene 4 000 L (*1)
Geosmin (mold smell) 4 000 L (*1)
Phenols 4 000 L (*1)
Carbon tetrachloride 4 000 L (*3)
Removable substances
Iron (particulate form) Can be removed. (*4)
Aluminum (neutral) Can be removed. (*4)
Replacement timing guideline for the lter
(cartridge)
Approx. 1 year (10 L of puried water used a day)
[Approx. 6 months (20 L of puried water used a day)] (*5)
Type of material used ABS resin
Filter material
Non‑woven fabric lter, Activated carbon, Ceramic,
Hollow ber membrane
Components which cannot be ltered out
Iron dissolved in water, heavy metals (silver, copper, etc.),
salt (seawater)
All gures given are for a water temperature of 20 °C.
This product cannot convert hard water into soft water.
(*1) This value is for a removal rate of 80 % based on JIS S 3201 tests.
(*2) This value is for a ltration ow volume of 50 % based on JIS S 3201 tests.
(*3) This value is for a removal rate of 80 % based on specication standard tests (JWPAS B
standards) stipulated by the Japan Water Purier Association (JWPA).
(*4) This substance is for a removal rate of 80 % based on specication standard tests (JWPAS B
standards) stipulated by the Japan Water Purier Association (JWPA).
Note that it is not stipulated as part of purication capacity.
(*5) This may be signicantly shorter depending on the volume of water used, water quality and
water pressure.