EasyManua.ls Logo

Panasonic TK-CJ600 - Specifications

Panasonic TK-CJ600
51 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EN49EN48
English
Product name TK-CJ600 TK-CJ300
Dimensions (width × depth × height) 135 (W) × 120 (D) × 75 (H) mm 125 (W) × 110 (D) × 75 (H) mm
Weight
Approx. 350 g
(Approx. 490 g when full of water)
Approx. 310 g
(Approx. 450 g when full of water)
Water temperature when using the main
unit
Puried water: Under 35 °C (Unpuried/shower: Under 80 °C)
Minimum usable dynamic water pressure 70 kPa
Filtration ow volume 1.8 L / min [At water pressure 100 kPa]
Cartridge Installed In the unit TK-CJ600C-EX
Purication capacity
Free residual chlorine 4 000 L (*1)
Turbidity 4 000 L (*2)
Total trihalomethane 4 000 L (*1)
Bromodichloromethane 4 000 L (*1)
Dibromochloromethane 4 000 L (*1)
Bromoform 4 000 L (*1)
Tetrachloroethylene 4 000 L (*1)
Trichloroethylene 4 000 L (*1)
CAT (pesticide) 4 000 L (*1)
2-MIB (mold smell) 4 000 L (*1)
Soluble lead 4 000 L (*1)
Specications
Purication capacity
Benzene 4 000 L (*1)
Geosmin (mold smell) 4 000 L (*1)
Phenols 4 000 L (*1)
Carbon tetrachloride 4 000 L (*3)
Removable substances
Iron (particulate form) Can be removed. (*4)
Aluminum (neutral) Can be removed. (*4)
Replacement timing guideline for the lter
(cartridge)
Approx. 1 year (10 L of puried water used a day)
[Approx. 6 months (20 L of puried water used a day)] (*5)
Type of material used ABS resin
Filter material
Non‑woven fabric lter, Activated carbon, Ceramic,
Hollow ber membrane
Components which cannot be ltered out
Iron dissolved in water, heavy metals (silver, copper, etc.),
salt (seawater)
All gures given are for a water temperature of 20 °C.
This product cannot convert hard water into soft water.
(*1) This value is for a removal rate of 80 % based on JIS S 3201 tests.
(*2) This value is for a ltration ow volume of 50 % based on JIS S 3201 tests.
(*3) This value is for a removal rate of 80 % based on specication standard tests (JWPAS B
standards) stipulated by the Japan Water Purier Association (JWPA).
(*4) This substance is for a removal rate of 80 % based on specication standard tests (JWPAS B
standards) stipulated by the Japan Water Purier Association (JWPA).
Note that it is not stipulated as part of purication capacity.
(*5) This may be signicantly shorter depending on the volume of water used, water quality and
water pressure.
TK-CJ600_CJ300_EXZ.indb 48-49 2022/01/05 15:32:30