25
4.1.2 Service Mode 1 (Function Parameter Setting)
Use the following procedure to change the function parameters.
Note
The following buttons provide these functions in the test mode:
Step Operation or Unit Condition LCD Display
1 Standby
2Press “FUNCTION” and then “7”.
3Press “MONITOR” four times, then press “*”.
4Press “1”.
5 Enter the Function Parameter Number.
Ex: Changing the "ALARM STATUS" -- Enter "001" and
press [SET].
6Press “START”.
7 Enter the new setting value.
Ex: Enter "3" for Constant.
8Press “START”. The new value will be stored and the
next parameter will be displayed.
9 Repeat steps 4 through 7 to change other Function
Parameters or Press “STOP” twice to return to standby.
"START" : The new setting value is stored in the machine.
"\/" : Scroll the function parameter number down.
"/\" : Scroll the function parameter number up.
OCT-12-2001 15:00
00%
SET MODE (1-6)
ENTER NO. OR
SERVICE MODE
ENTER NO. OR
PARAMETER (000-199)
ENTER PARAMETER #_
PARAMETER #001
ALARM STATUS?
ALARM STATUS:Timer
1:OFF 2:Tmr 3:CONST
ALARM STATUS:Const.
1:OFF 2:Tmr 3:CONST
PARAMETER #002
STOP COMM.JRNL?
OCT-12-2001 15:00
00%