Wiring schematic diagram
Set up correctly according to the following wiring schematic diagrams and “Wire type and
distance”.
Door (Door Opener) 2 *
4
Door (Door Opener) 1 *
4
PBX*
3
Door station 2Door station 1 *
1
(Non polar) (Non polar)
Main monitor station
Ter minal box
(4-conductor wiring)
(Non polar)
(Non polar)
(Non polar)
Power plug
(100
240 V AC)
You can also connect
an optional lobby
station for apartment
complexes.*
2
Optional equipment
(Refer to pages 42-43 in the Operating Instructions.)
*
1
For VL-MW250BX users: The door station is optional (not included).
*
2
Connecting an optional lobby station for apartment complexes
Be sure to perform the following to ensure proper operation:
LConnect to terminal D1/D2 on the main monitor station.
LAfter connecting to the main monitor station, change the setting of “LOBBY
CONNECTION” to “YES” using the main monitor station. (Refer to page 38 in the
Operating Instructions.)
*
3
For information about compatible PBXs, refer to page 4 in the Operating Instructions.
*
4
Connecting a door opener
LBefore connecting to a door opener, make sure that:
– S1/S2/S3/S4 terminal: Normally open/Actively short
– The door opener is less than 30 V AC (1 A), 24 V DC (1 A).
S1/S2/S3/S4 terminal on the main monitor station is not the power supply to the door
opener. If the door opener needs a power supply device to connect to the main monitor
station, contact the dealer where you purchased the door opener.
L The door opener for the door station connected to terminal D1/D2 must be
connected to terminal S1/S2. The other door opener for the door station connected
to terminal D3/D4 must be connected to terminal S3/S4.
L You can connect up to 2 door openers to the main monitor station. If the main monitor
station is connected to a PBX, one of the 2 door openers can be connected to the PBX
and operated from the PBX extensions.
Note:
LConnect the plug to the power outlet which is easily accessible. In case the plug is not
easily accessible, you should install the main disconnect device near the product. The main
disconnect device needs to be certi ed or comply with an appropriate standard. (See “To
connect the plug to the power outlet which is not easily accessible”.)
LWhen you move the main monitor station, make sure the PBX is disconnected.
LThe door opener wiring schematic diagram is only an example. Refer to the wiring
instructions provided with your door opener and PBX for details.
Wire type and distance
LWire (between the main monitor station and the door station):
Type Distance Loop resistance
General cable CAT-3 Maximum 50 m
10 Ω or lower
General cable 22 AWG (ø 0.65) Maximum 100 m
LWire (between the main monitor station and PBX):
Type: General cable CAT-3 or 22 AWG (ø 0.65)
Distance: Maximum 100 m