Appendix
Heating capacity in relation to supply water and outside temperature
Aquarea HT
Aquarea HT – Monobloc system
Heating capacity [kW] of individual models of the monobloc system for different outside temperatures and
a supply water temperature of 35 or 65 °C.
-15-20 -10 -5 0
16
14
12
10
8
6
4
2
0
5101
Outside temperature [°C]
12 kW (single and three phase)
9 kW (single and three phase)
Supply water temperature 35 °C
Supply water temperature 65 °C
Outside
temperature
Supply water temperature Models
30 35 40 45 50 55 60 65 9 kW (single
and three phase)
WH-MHF09D3E5
WH-MHF09D3E8
-15 9.0 9.0 8.9 8.8 8.5 8.5 8.0 7.8
-7 9.0 9.0 9.0 8.9 8.9 8.9 8.9 8.9
2 9.0 9.0 9.0 9.0 9.0 9.0 9.0 9.0
7 9.0 9.0 9.0 9.0 9.0 9.0 9.0 9.0
25 12.0 12.0 12.0 10.8 10.2 11.2 10.0 9.8
30 35 40 45 50 55 60 65 12 kW (single
and three phase)
WH-MHF12D6E5
WH-MHF12D9E8
-15 12.0 12.0 11.0 10.6 10.3 9.7 9.0 8.0
-7 12.0 12.0 11.5 11.2 10.8 10.1 9.9 9.6
2 12.0 12.0 11.5 11.3 11.0 10.8 10.7 10.3
7 12.0 12.0 12.0 12.0 12.0 12.0 12.0 12.0
25 12.0 12.0 12.0 12.0 12.0 12.0 12.0 12.0
Heating capacity [kW] of individual models of the monobloc system for different supply water and outside temperatures [°C].