22 User’s Guide
NOTE1: If you have access to both partitions, buttons [1]
and [2] will flash. Press the button corresponding to the
desired partition. The [
BYP] button will flash and any zones
that are already bypassed will illuminate.
4.6.1 Bypass Recall Feature
After disarming the system, the bypass entries are erased.
The Bypass Recall Feature reinstates the previous bypass
entries saved in memory. This eliminates the need to manually
re-program the bypass entries every time you arm the system.
How do I Program Bypass Entries?
1) Press the [
BYP] button.
2) Enter your [
ACCESS CODE]. (see Note1)
3) Illuminate the button(s) corresponding to the zone(s) you
wish to bypass by pressing the corresponding button.
Press the button again to turn it off. Press the [FORCE]
button to erase all the current zone bypass entries.
4) Once you have entered the desired bypass entries,
press the [
ENTER] button to accept these entries.
THE [BYP] button will turn on when zones are bypassed. The
next time the system is armed, the zones will be bypassed.
How Do I Recall Bypass Entries?
1) Press the [
BYP] button.
2) Enter your [
ACCESS CODE]. (see Note1)
3) Press the [
BYP] button.
Previously bypassed zones will illuminate.
4) Press the [ENTER] button.
1686EU04.fm Page 22 Tuesday, August 13, 2002 10:01 AM

Other manuals for Paradox SPECTRA 1686H

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox SPECTRA 1686H and is the answer not in the manual?

Paradox SPECTRA 1686H Specifications

General IconGeneral
BrandParadox
ModelSPECTRA 1686H
CategoryControl Panel
LanguageEnglish

Related product manuals