HY13-1597-01/US
3Z Motor Service Procedure
3ZG Series
Parker Hannin Corporation
Hydraulic Pump & Motor Division
Greeneville, TN 37745 US
19
Assembly
Roll-gerotor
set
Valve
Drive
Bottom
of tooth
CCW CW
A
A
B
B
Timing
mark
Valve
Plate
NOTE
Install #2 Drive Link
Install Balance Plate
NOTE
Install Channel Plate
Standard Rotation
Procedure
Figure41
Figure42
TimingAlignmentdiagramfor
Reference(Figure41)
Installthesmallerdrivelinkinto
therotorset.(Figure42)
Makesuretolineuptheguide
pinswiththepinholesinthe
motorbody.
Reinstallthebalanceplateonto
themotor.(Figure43)
Makesuretolineuptheguide
pinswiththepinholesinthe
motorbody.
Placethechannelplateovertop
ofthebalanceplate.(Figure44)
Lookingstraightdownatthe
manifoldfromabove,alignthe
alignmentmarkonthedrivelink
withanyoneoftheholesonthe
discvalveandsetthediscvalve
downontothedrivelink.
Rotatethedrivelink15degrees
counterclockwisetoachieve
standardrotation.(Figure45)
Figure43
Figure44
Figure45