D-190 Programming
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames E & F
Parameter Specifications
The headings for the Parameter tables are described below.
PREF
A numeric identification of the parameter. It is used to identify the source and destinations of internal
links.
Name
The parameter name.
Block
The menu page and function block under which the parameter is stored.
Type
REAL
INT
BOOL
ENUM
STRING
WORD
Floating point value
Integer value
A Boolean (bit) representing FALSE or TRUE
An enumerated value representing a selection
An ASCII string
16 Bit hexadecimal number
Range
This varies with parameter type:
REAL, INT
BOOL
ENUM
STRING
WORD
The upper and lower limits of the parameter
0 = FALSE, 1 = TRUE
A list of possible selections for that parameter
Specified number of characters
0000 to FFFF (hexadecimal), numbered lists show Bit numbers
Note
Decimal Places:” signifies an indeterminable number of units. An “x” signifies a decimal place,
e.g. .xx % could represent 100.00 %.
Default
The default value of the parameter.
ro\rw
Denotes a Read-Only (ro) or Read-Write (rw) parameter.

Table of Contents

Other manuals for Parker 890

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker 890 and is the answer not in the manual?

Parker 890 Specifications

General IconGeneral
BrandParker
Model890
CategoryController
LanguageEnglish

Related product manuals