C. Maintenance instructions are supplied with appropriate
rebuild kits. Kit part numbers are listed on the assem-
bly drawing.
Section 11.0
Trouble Shooting - Pneumatic Section
Problem: Pump will not operate with low air pressure.
Cause: Excessive friction of o-rings on the spool valve has
increased the pressure required to move spool.
Solution: Replace and lubricate the o-rings on spool
Problem: Pump can only be actuated at high air pressure.
Cause: Air is leaking through the o-rings between
the end cap and air cylinder.
Solution: Replace and lubricate o-ring on lip of the
end cap.
Problem: Pump will not run and air escaped through
the exhaust mufer.
Cause: a) Spool valve o-rings are leaking.
b) Spool sleeve o-rings are leaking.
c)
Outside o-ring(s) on air piston(s) is leaking.
d) Seal between air piston and liquid plunger
is leaking.
Solution:
a)
Replace and lubricate spool valve o-rings.
b) Replace and lubricate sleeve o-rings.
c)
Replace and lubricate air piston o-ring(s).
Before attempting to disassemble the pump or loosen
ttings in a pressure system, be sure that liquid
pressure has been totally vented.
WARNING
Before attempting to perform maintenance on the
pump, assure that air supply pressure is shut off
and vented from the pump.
WARNING
d) Replace o-ring on bottom plunger (two piece
plunger designs), or add Loctite 2760 thread
locker with sealant on plunger threads (one piece
plunger designs).
Problem: Pump will not run and air escapes through
the pilot valve vent in the bottom end cap.
Cause: Pilot valve gasket or o-ring is not sealing in
the bottom cap.
Solution: Replace and lubricate pilot valve gasket
and o-ring. If necessary, also replace the
tappet rod.
Problem: Pump operates at a high frequency and
short strokes.
Cause:
The top or bottom pilot valves are defective.
Solution: Replace and lubricate both pilot valve gaskets
and o-rings. If necessary also replace the
tappet rods.
Problem: Air leaking at isolation chamber drain connection.
Cause: The rod seal and/or the o-ring on the seal retainer
is leaking.
Solution: Replace and lubricate both the o-ring and rod
seal assembly.
Problem: Pump functions slowly or doesn't operate at all.
Cause: a) Condensation from air supply is freez-
ing the spool valve.
b) Air mufer is clogged.
Solution: a)
Stop pump for a short period and re-
place or add a mist separator in the air line.
b) Clean or replace air mufer.