7
Parker Autoclave Engineers
Instrumentation Products Division
Erie, PA  USA
www.autoclave.com   |   Cat. 02-9309ME
C. Maintenance instructions are supplied with appropriate 
rebuild kits. Kit part numbers are listed on the assem-
bly drawing.
Section 11.0
Trouble Shooting - Pneumatic Section
Problem:  Pump will not operate with low air pressure.
Cause:   Excessive friction of o-rings on the spool valve has  
  increased the pressure required to move spool.
Solution:   Replace and lubricate the o-rings on spool
Problem:  Pump can only be actuated at high air pressure.
Cause:   Air is leaking through the o-rings between  
  the end cap and air cylinder.
Solution:   Replace and lubricate o-ring on lip of the  
  end cap.
Problem:  Pump will not run and air escaped through  
  the exhaust mufer. 
Cause:   a)  Spool valve o-rings are leaking.
  b)  Spool sleeve o-rings are leaking.
 c) 
Outside o-ring(s) on air piston(s) is leaking.
  d)  Seal between air piston and liquid plunger  
    is leaking.
Solution:  
a) 
Replace and lubricate spool valve o-rings.
  b)  Replace and lubricate sleeve o-rings.
  c)  
Replace and lubricate air piston o-ring(s).
Before attempting to disassemble the pump or loosen 
 ttings in a pressure system, be sure that liquid  
pressure has been totally vented.
WARNING
Before attempting to perform maintenance on the  
pump, assure that air supply pressure is shut off 
and vented from the pump.
WARNING
  d)  Replace o-ring on bottom plunger (two piece  
    plunger designs), or add Loctite 2760 thread  
    locker with sealant on plunger threads (one piece  
    plunger designs).
Problem:  Pump will not run and air escapes through  
  the pilot valve vent in the bottom end cap.
Cause:   Pilot valve gasket or o-ring is not sealing in  
  the bottom cap.
Solution:   Replace and lubricate pilot valve gasket  
  and o-ring. If necessary, also replace the  
  tappet rod.
Problem:  Pump operates at a high frequency and  
  short strokes.
Cause:  
The top or bottom pilot valves are defective.
Solution:   Replace and lubricate both pilot valve gaskets  
  and o-rings. If necessary also replace the  
  tappet rods.
Problem:   Air leaking at isolation chamber drain connection.
Cause:   The rod seal and/or the o-ring on the seal retainer
  is leaking.
Solution:   Replace and lubricate both the o-ring and rod
  seal assembly.
Problem:   Pump functions slowly or doesn't operate at all.
Cause:   a)  Condensation from air supply is freez- 
    ing the spool valve.
  b)  Air mufer is clogged.
Solution:   a) 
Stop pump for a short period and re- 
    place or add a mist separator in the air line.
  b)  Clean or replace air mufer.