EN | User Manual Annex with technical documentation
46 BSP-MT 10-95/D3
Drying agent
Chamber 1 100 % molecular sieve
Chamber 2 100 % molecular sieve
Chamber 3
down middle top
33 % activated carbon 33 % catalyst 33 % activated carbon
Limits for breathing air
Industrial breathing air with
brating-
air unit
BSP-MT
Medical air
Europe UK USA Australia Europe
EN 12021 BS 4275 ANSI/CGA AS 1715 Ph.European
Carbon
monoxide CO
< 15ppm < 5ppm < 10ppm < 10ppm < 2ppm < 5ppm
Carbon
dioxidv CO
2
< 500ppm < 500ppm < 1000ppm < 800 ppm < 150ppm < 500ppm
humidity H
2
O < 5 °C * < 5 °C * < 10 °F * <100mg/m < 15 ppm** < 67 ppm
oxygen O
2
21 (±1) % 20 – 23 % 21,5 %
20,8–21,1% 20,4 – 21,4 %
Oil quantity
< 0,5 mg/m < 0,5 mg/m < 0,5 mg/m < 1,0 mg/m < 0,003mg/m < 0,1 mg/m
odoriferous / aro-
matic substance
Free free Free Free Free free
Sufur dioxideSO
2
< 0,1 ppm < 1 ppm
mitrous gases
NO/NO
2
< 1 ppm < 2 ppm
* Pressure dewpoint below inlet temperature ; **Corresponding pressure dewpoint -50°C to
-45°C at 7 bare . .. All values refer to customary concentration levels present in the inlet air.