N2 Compact Nitrogen Gas Generator - User Guide. ©2019.
OXYGEN CELL REPLACEMENT
EXHAUST SILENCER REPLACEMENT
Unscrew the oxygen cell lead (01) and solenoid plugs (02) then remove the 4-20mA connections and move the lead to prevent
obstruction. Disconnect the tubing from the 3-way ball valve (03) to the regulator (04). Loosen the regulator retaining collar (05)
then unscrew the top retaining screw (06) of the assembly and remove. Cut the tie wrap and unscrew the oxygen sensor. Remove
the used cell and replace with the new one.
Note: Ensure to wear gloves when handling the new cell to prevent causing any damage.
Re t in reverse order.
e exhaust silencer is located under the inlet manifold assembly.
Unscrew the element from the exhaust port (01) and discard (02).
Fit the replacement element ensuring that it is fully engaged onto the pipe  tting and secure it hand tight.
01
02
01
02
30
N2 Compact Nitrogen Gas Generator - User Guide. ©2020.
02
04
05
03
06
01