INSERTION OF
REPLACEMENT ELEMENT
INTO FILTER BOWL
REPLACEMENT OF FILTER
HEAD O RING
RECONNECTING THE FILTER BOWL WITH HEAD
Insert the new element into the  lter bowl ensuring that
the lugs are seated correctly in the grooves.
Replace the O-ring located in the  lter head with the new
O-ring provided.
Re t the  lter bowl and head ensuring that the threads are fully engaged (01) and the locking details are aligned (02).
Note: To ensure that the bowl is fully engaged into the head, the 010 bowl requires 360
o
of rotation until the thread stop.
34
N2 Compact Nitrogen Gas Generator - User Guide. ©2020
Ensure to lubricate the O-ring and
threads with a suitable acid free
Petroleum jelly.
02
01
Upto 720
o