INLET PARAMETERS
ENVIRONMENTAL
PARAMETERS
PORT CONNECTIONS
Inlet Air Quality ISO 8573-1:2001 Class 2.2.1
Inlet Pressure
6 - 10 bar g
87 - 145 psi g
Inlet Temperature
5 - 50
o
C
(41 - 122
o
F)
Ambient Temperature
5 - 50
o
C
(41 - 122
o
F)
Humidity 29% @ 50oC (80% max < 31
o
C)
IP Rating IP20 / NEMA 1
Pollution Degree 2
Installation Category II
Altitude
< 2000 m
(6562 ft)
Noise <80 dB (A)
Air Inlet G1/2
N
2
Outlet to Buffer G1/2
N
2
Inlet from Buffer G1/2
N
2
Outlet G1/2
Notes:
*  e generator does not require adjustment when connecting to 115v and 230v electrical supplies.
**  e power rating speci ed is for the generator alone and does not take in to account any pre-treatment dryer connected to the dryer supply
terminals of the generator.
***  e dryer is fed directly from the generator supply.
PACKED WEIGHTS
AND DIMENSIONS
ELECTRICAL PARAMETERS
Dimensions mm / (ins)
Weight
kg / (Ibs)
LWD
N2C-2
758
(29.84)
548
(21.57)
1215
(47.83)
135.5
(298.7)
N2C-4
808
(31.81)
548
(21.57)
1215
(47.83)
188
(414.5)
N2C-6
978
(38.5)
548
(21.57)
1215
(47.83)
246
(542.3)
N2C-8
1147
(45.16)
548
(21.57)
1215
(47.83)
303
(668)
Generator Supply* 115 / 230 ± 10% Vac 50/60 Hz
Generator Power** 80W
Fuse
3.15 A
(Anti Surge (T), 250v, 5 x 20mm HBC,
Breaking Capacity 1500A @ 250v,
IEC 60127, UL R/C Fuse)
Max Dryer Power*** 100W