Nitrogen Gas Generator
MIDIGAS 2 - 6
Original Language
User Guide / Gebruikershandleidi / Benutzerhandbuch /
Guide d’utilisation / Guía del usuario / Manuale utente
EN
ES

Table of Contents

Questions and Answers

  • B
    Brandon PerezAug 4, 2025
    What to do if Parker MIDIGAS 2 Inverter has no or low gas outlet pressure?
    • T
      Timothy NguyenAug 4, 2025
      If the Parker Inverter shows no or low gas outlet pressure, first check the piping and connection points for any external leaks and repair them if necessary. Then, open the access door and inspect all connection points for internal leaks, repairing as needed. Also, consider that the generator might require a service, so check the service schedule and perform the required service.
  • B
    Brandi McgeeAug 9, 2025
    What to do if Parker MIDIGAS 2 shows low inlet pressure?
    • L
      Lori PittsAug 9, 2025
      If your Parker Inverter is showing a low inlet pressure, start by checking the service schedules for the filters and perform the required service, as the pre-filtration within the system may be approaching the end of its operational life. Next, verify that the compressed air delivered to the dryer meets the requirements specified within the documentation provided with the dryer, as the pretreatment dryer may be overflowed or operating at a reduced system pressure. Check the position of all isolation valves, and inspect the piping and connection points for external leaks, repairing as necessary.
  • P
    Philip SmithAug 16, 2025
    What to do if Parker MIDIGAS 2 Inverter has power but status indicators are off?
    • W
      wigginsdianeAug 16, 2025
      If the status indicators and display on your Parker Inverter are not illuminated, even when power is connected, first, ensure that there is power to the generator supply terminals on terminal block “TB1”. Next, check fuse “F1” on terminal block “TB1”; if it's blown, disconnect the electrical supply and replace it. Finally, open the access door and check that the 26-way ribbon cable is connected between the controller and JP22 on the control board.
  • C
    Charles RodriguezAug 22, 2025
    What causes high oxygen concentration in Parker MIDIGAS 2?
    • J
      jamesguerreroAug 22, 2025
      If your Parker Inverter has a high oxygen concentration, the first step is to replace the oxygen cell, as it may be defective. Also, open the access door and check all connection points for leaks in the system piping, and repair them as necessary.
  • A
    Antonio FuentesAug 28, 2025
    How to fix excessive noise in Parker MIDIGAS 2?
    • B
      bryantravisAug 28, 2025
      If your Parker Inverter is producing excessive noise or vibration, check that the exhaust silencer is securely fitted in place. Also, check the exhaust valves and verify that the coils are secure. Contact Parker domnick hunter for advice.

Summary

Safety Information

USER RESPONSIBILITY

User is solely responsible for final selection, system components, and meeting all application requirements.

Description

Technical Specification

Detailed specifications including flow rates, pressure, power, dimensions, and environmental parameters.

Installation and Commissioning

Mechanical Installation

Step-by-step instructions for connecting the generator's piping and valves to the system.

Electrical Installation

Procedures for correctly wiring the generator, including supply, dryer, purge economy, and alarm contacts.

Operating the Generator

Starting the Generator

Step-by-step guide on how to safely start the nitrogen generator.

Stopping and Depressurising the Generator

Procedure for safely shutting down and depressurising the generator.

Servicing

Oxygen Analyser Calibration

Procedure for calibrating the oxygen analyser using gas supply or independent analyser.

Troubleshooting

Fault Diagnosis and Remedies

Guide to identify probable causes and remedies for common operational faults and issues.

Parker MIDIGAS 2 Specifications

General IconGeneral
BrandParker
ModelMIDIGAS 2
CategoryInverter
LanguageEnglish