20
Performance Data
165/175 Series: Permanent Magnet Motors - AY
Note: BY motor (24 VDC) flow will be equivalent to the AY curves;
current draw will be about 1/2 of the AY motor values.
8
10
12
14
16
4
5
6
7
8
On Time - %
S3
Time - Minutes
S2
Percentage of "on" time in a
repetitive 10 minute cycle.
S3 (12 V)
S3
0
2
4
6
0
1
2
3
0 20 40 60 80 100 120 140 160 180 200
On
Current Draw - Amps
Time at constant load followed by
"off" time to allow the motor to cool
to ambient temperature.
S2 (12 V)
S2 (24 V)
S2
S3 (24 V)
Instruction Manual
Oildyne 108/118 and 165/175 Series
Hydraulic Power Units
Bulletin HY22-3210A/US
Parker Hannifin
HPS Division
New Hope, MN 55428 USA
0
50
100
150
200
250
300
350
0 500 1000 1500 2000 2500 3000
Output Flow -lpm (cipm)
25
0
50
75
100
125
150
175
Current - Amps
650 Pump
(.065 cipr)
327 Pump
(.032 cipr)
500 Pump
(.050 cipr)
0.82
(50)
1.64
(100)
2.46
(150)
3.28
(200)
4.10
(250)
4.92
(300)
5.74
(350)
34
(500)
69
(1000)
103
(1500)
138
(2000)
172
(2500)
207
(3000)
241
(3500)
Pressure - bar (psi)
Performance Data
DC Motor Duty Cycle Characteristics